SV-217414r557520_rule
V-217414
SRG-APP-000373-NDM-000298
F5BI-DM-000201
CAT II
10
Configure the BIG-IP appliance to synchronize internal information system clocks with the primary and secondary time sources located in different geographic regions using redundant authoritative time sources.
Determine if the BIG-IP appliance is configured to synchronize internal information system clocks with the primary and secondary time sources located in different geographic regions using redundant authoritative time sources.
Navigate to the BIG-IP System manager >> Configuration >> Device >> NTP.
Verify there is a primary time source and a secondary time source configured that are in different geographic regions.
If the BIG-IP appliance is not configured to synchronize internal information system clocks with the primary and secondary time sources located in different geographic regions using redundant authoritative time sources, this is a finding.
V-217414
False
F5BI-DM-000201
Determine if the BIG-IP appliance is configured to synchronize internal information system clocks with the primary and secondary time sources located in different geographic regions using redundant authoritative time sources.
Navigate to the BIG-IP System manager >> Configuration >> Device >> NTP.
Verify there is a primary time source and a secondary time source configured that are in different geographic regions.
If the BIG-IP appliance is not configured to synchronize internal information system clocks with the primary and secondary time sources located in different geographic regions using redundant authoritative time sources, this is a finding.
M