SV-223901r561402_rule
V-223901
SRG-OS-000080-GPOS-00048
TSS0-ES-000280
CAT III
10
Configure the WRITE or greater access to libraries containing PPT modules to be limited to system programmers only and all WRITE or greater access is logged.
Review program entries in the IBM Program Properties Table (PPT). You may use a third-party product to examine these entries however, to determine program entries issue the following command from an ISPF command line:
TSO ISRDDN LOAD IEFSDPPT
Press Enter.
For each module identified in the "eyecatcher" if all of the following are untrue, this is not a finding.
If any of the following is true, this is a finding.
The ACP data set rules for libraries that contain PPT modules do not restrict WRITE or greater access to only z/OS systems programming personnel.
The ACP data set rules for libraries that contain PPT modules do not specify that all WRITE or greater access will be logged.
V-223901
False
TSS0-ES-000280
Review program entries in the IBM Program Properties Table (PPT). You may use a third-party product to examine these entries however, to determine program entries issue the following command from an ISPF command line:
TSO ISRDDN LOAD IEFSDPPT
Press Enter.
For each module identified in the "eyecatcher" if all of the following are untrue, this is not a finding.
If any of the following is true, this is a finding.
The ACP data set rules for libraries that contain PPT modules do not restrict WRITE or greater access to only z/OS systems programming personnel.
The ACP data set rules for libraries that contain PPT modules do not specify that all WRITE or greater access will be logged.
M
4102