STIGQter STIGQter: STIG Summary: EDB Postgres Advanced Server v11 on Windows Security Technical Implementation Guide Version: 2 Release: 1 Benchmark Date: 23 Oct 2020:

Database contents must be protected from unauthorized and unintended information transfer by enforcement of a data-transfer policy.

DISA Rule

SV-224180r508023_rule

Vulnerability Number

V-224180

Group Title

SRG-APP-000243-DB-000128

Rule Version

EP11-00-005900

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

Modify any code used for moving data from production to development/test systems to comply with the organization-defined data transfer policy and to ensure copies of production data are not left in unsecured locations.

Check Contents

Review the procedures for the refreshing of development/test data from production.

Review any scripts or code that exist for the movement of production data to development/test systems or to any other location or for any other purpose.

Verify that copies of production data are not left in unprotected locations.

If the code that exists for data movement does not comply with the organization-defined data transfer policy and/or fails to remove any copies of production data from unprotected locations, this is a finding.

Vulnerability Number

V-224180

Documentable

False

Rule Version

EP11-00-005900

Severity Override Guidance

Review the procedures for the refreshing of development/test data from production.

Review any scripts or code that exist for the movement of production data to development/test systems or to any other location or for any other purpose.

Verify that copies of production data are not left in unprotected locations.

If the code that exists for data movement does not comply with the organization-defined data transfer policy and/or fails to remove any copies of production data from unprotected locations, this is a finding.

Check Content Reference