STIGQter STIGQter: STIG Summary: F5 BIG-IP Device Management 11.x Security Technical Implementation Guide Version: 2 Release: 1 Benchmark Date: 23 Oct 2020:

The BIG-IP appliance must be configured to alert the ISSO and SA (at a minimum) in the event of an audit processing failure.

DISA Rule

SV-228983r557520_rule

Vulnerability Number

V-228983

Group Title

SRG-APP-000516-NDM-000317

Rule Version

F5BI-DM-000067

Severity

CAT III

CCI(s)

Weight

10

Fix Recommendation

Configure the BIG-IP appliance to alert the ISSO and SA (at a minimum) in the event of an audit processing failure.

Check Contents

Verify the BIG-IP appliance is configured to alert the ISSO and SA (at a minimum) in the event of an audit processing failure.

Navigate to the BIG-IP System manager >> System >> Logs >> Configuration >> Options.

Verify "MCP" under the "Audit Logging" section is set to Debug.

If the BIG-IP appliance is not configured to alert in the event of an audit processing failure, this is a finding.

Vulnerability Number

V-228983

Documentable

False

Rule Version

F5BI-DM-000067

Severity Override Guidance

Verify the BIG-IP appliance is configured to alert the ISSO and SA (at a minimum) in the event of an audit processing failure.

Navigate to the BIG-IP System manager >> System >> Logs >> Configuration >> Options.

Verify "MCP" under the "Audit Logging" section is set to Debug.

If the BIG-IP appliance is not configured to alert in the event of an audit processing failure, this is a finding.

Check Content Reference

M

Target Key

4036

Comments