SV-28613r2_rule
V-17452
ZB000030
ZNETA030
CAT II
10
The NetView system programmer and the ISSO will ensure that a product's Started Task(s) is properly Identified / defined to the System ACP.
If the product requires a Started Task, verify that it is properly defined to the System ACP with the proper attributes.
Most installation manuals will indicate how the Started Task is identified and any additional attributes that must be specified.
Example:
SET LID
CHANGE NETVIEW STC MUSASS NO-SMC
Refer to the following report produced by the ACF2 Data Collection:
- ACF2CMDS.RPT(ATTSTC)
If the logonid for the NetView started task(s) includes MUSASS and NO-SMC, there is NO FINDING.
If the logonid for the NetView started task(s) is not defined or does not include MUSASS and/or NO-SMC, this is a FINDING.
V-17452
False
ZNETA030
Refer to the following report produced by the ACF2 Data Collection:
- ACF2CMDS.RPT(ATTSTC)
If the logonid for the NetView started task(s) includes MUSASS and NO-SMC, there is NO FINDING.
If the logonid for the NetView started task(s) is not defined or does not include MUSASS and/or NO-SMC, this is a FINDING.
M
1859