STIGQter STIGQter: STIG Summary: z/OS BMC MAINVIEW for z/OS for TSS STIG Version: 6 Release: 7 Benchmark Date: 20 Jan 2015:

BMC MAINVIEW for z/OS STC data sets are not properly protected.

DISA Rule

SV-37724r1_rule

Vulnerability Number

V-17067

Group Title

ZB000001

Rule Version

ZMVZT001

Severity

CAT II

CCI(s)

Weight

10

Fix Recommendation

The IAO will ensure that update and allocate access to BMC MAINVIEW for z/OS STC data sets is limited to System Programmers and/or BMC MAINVIEW for z/OS’s STC(s) and/or batch user(s) only. Read access can be given to auditors and authorized users.

The installing Systems Programmer will identify and document the product data sets and categorize them according to who will have update and alter access and if required that all update and allocate access is logged. He will identify if any additional groups have update and/or alter access for specific data sets, and once documented he will work with the IAO to see that they are properly restricted to the ACP (Access Control Program) active on the system.

Data sets to be protected will be:
SYS3.BMCVIEW (data sets that are altered by the product’s STCs, this can be more specific)

The following commands are provided as a sample for implementing data set controls:

TSS PERMIT(<syspaudt>) DSN(SYS3.BMCVIEW) ACCESS(ALL)
TSS PERMIT(<tstcaudt>) DSN(SYS3.BMCVIEW) ACCESS(ALL)
TSS PERMIT(MAINVIEW STCs) DSN(SYS3.BMCVIEW) ACCESS(ALL)
TSS PERMIT(<audtaudt>) DSN(SYS3.BMCVIEW) ACCESS(R)
TSS PERMIT(authorize user) DSN(SYS3.BMCVIEW) ACCESS(R)

Check Contents

Refer to the following report produced by the Data Set and Resource Data Collection:

- SENSITVE.RPT(MVZSTC)

Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:

- PDI(ZMVZ0001)

Verify that the accesses to the BMC MAINVIEW for z/OS STC data sets are properly restricted.

___ The TSS data set rules for the data sets restricts READ access to auditors and authorized users.

___ The TSS data set rules for the data sets restricts UPDATE and/or ALL access to systems programming personnel.

___ The TSS data set rules for the data sets restricts UPDATE and/or ALL access to the BMC MAINVIEW for z/OS’s STC(s) and/or batch user(s).

Vulnerability Number

V-17067

Documentable

False

Rule Version

ZMVZT001

Severity Override Guidance

Refer to the following report produced by the Data Set and Resource Data Collection:

- SENSITVE.RPT(MVZSTC)

Automated Analysis
Refer to the following report produced by the Data Set and Resource Data Collection:

- PDI(ZMVZ0001)

Verify that the accesses to the BMC MAINVIEW for z/OS STC data sets are properly restricted.

___ The TSS data set rules for the data sets restricts READ access to auditors and authorized users.

___ The TSS data set rules for the data sets restricts UPDATE and/or ALL access to systems programming personnel.

___ The TSS data set rules for the data sets restricts UPDATE and/or ALL access to the BMC MAINVIEW for z/OS’s STC(s) and/or batch user(s).

Check Content Reference

M

Responsibility

Systems Programmer

Target Key

2093

Comments