SV-80577r1_rule
V-66087
SRG-NET-000512-L2S-000008
HFFS-L2-000025
CAT II
10
Remove the assignment of the default VLAN from all access switch ports.
<HP>display vlan 1
[HP-vlan2]port GigabitEthernet 1/0/1 to GigabitEthernet 1/0/48
[HP-GigabitEthernet1/0/1]shutdown
Review the HP FlexFabric Switch configurations and verify that no access switch ports have been assigned membership to the default VLAN (i.e., VLAN 1). A good method of ensuring there is not membership to the default VLAN is to have it disabled (i.e., shutdown) on the switch.
If there are access switch ports assigned to the default VLAN, this is a finding.
<HP>display vlan 1
VLAN ID: 1
VLAN type: Static
Route interface: Configured:
Description: VLAN 0001
Name: VLAN 0001
Tagged ports: None
Untagged ports:
GigabitEthernet1/0/1 GigabitEthernet1/0/2
GigabitEthernet1/0/3 GigabitEthernet1/0/4
[HP-GigabitEthernet1/0/12]shutdown
V-66087
False
HFFS-L2-000025
Review the HP FlexFabric Switch configurations and verify that no access switch ports have been assigned membership to the default VLAN (i.e., VLAN 1). A good method of ensuring there is not membership to the default VLAN is to have it disabled (i.e., shutdown) on the switch.
If there are access switch ports assigned to the default VLAN, this is a finding.
<HP>display vlan 1
VLAN ID: 1
VLAN type: Static
Route interface: Configured:
Description: VLAN 0001
Name: VLAN 0001
Tagged ports: None
Untagged ports:
GigabitEthernet1/0/1 GigabitEthernet1/0/2
GigabitEthernet1/0/3 GigabitEthernet1/0/4
[HP-GigabitEthernet1/0/12]shutdown
M
2977